Skip to Content
Search
Your Cart
Loading...
Categories
Loading...
Home Search 0 Wishlist
Category

Pressure switches, measuring instruments and flow monitors

FM24-10-W-45
Flow monitors Series FM24; Viscosity compensated ...600mm²/s; Body Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication; Switch unit Schließer; Connection 1"; Switching range 15...45L/min; Maximum pressure 300bar; U max. 250V; I max. 3A; Length 130mm
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1" 130 mm NO contact 250 V 3 A 300 bar 15...45 l/min FM24-10-W-45
Flow monitors Series FM24

Flow monitors Series FM24

Viscosity compensated ...600mm²/s; Body Nickel plated brass; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication

Grundversion
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type Sequence
1" 130 mm NO contact 250 V 3 A 250 bar 30...110 l/min FM24-10-N-110-04 33060001
1" 130 mm Change-over contact 250 V 1,5 A - 1...4 l/min FM24-10-N-4-01 33060002
FM24-10-W-60
Flow monitors Series FM24; Viscosity compensated ...600mm²/s; Body Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication; Switch unit Schließer; Connection 1"; Switching range 20...60L/min; Maximum pressure 300bar; U max. 250V; I max. 3A; Length 130mm
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1" 130 mm NO contact 250 V 3 A 300 bar 20...60 l/min FM24-10-W-60
FM24-10-N-30-02
Flow monitors Series FM24; Viscosity compensated ...600mm²/s; Body Nickel plated brass; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication; Switch unit Wechsler (SPS); Connection 1"; Switching range 10...30L/min; Maximum pressure 250bar; U max. 250V; I max. 1A; For SPS; Length 130mm
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1" 130 mm Change-over contact 250 V 1,5 A - 10...30 l/min FM24-10-N-30-02
FM24-12-W-1,5
Flow monitors Series FM24; Viscosity compensated ...600mm²/s; Body Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication; Switch unit Schließer; Connection 1/2"; Switching range 0,5...1,5L/min; Maximum pressure 300bar; U max. 250V; I max. 3A; Length 152mm
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1/2" 152 mm NO contact 250 V 3 A 300 bar 0,5...1,5 l/min FM24-12-W-1,5
FM24-10-N-4-03
flow monitors series FM24; viscosity compensated ...600mm²/s; body nickel plated brass; for any mounting position; medium temperature max. 120°C; oil scale; application: monitoring of lubrication; switch unit change-over contact; connection G1"; switching range 1...4l/min; maximum pressure 250bar; U max. 250V; I max. 1,5A; length 130mm
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1" 130 mm Change-over contact 250 V 1,5 A 250 bar 1...4 l/min FM24-10-N-4-03
FM24-12-W-4
Flow monitors Series FM24; Viscosity compensated ...600mm²/s; Body Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication; Switch unit Schließer; Connection 1/2"; Switching range 1...4L/min; Maximum pressure 300bar; U max. 250V; I max. 3A; Length 152mm
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1/2" 152 mm NO contact 250 V 3 A 300 bar 1...4 l/min FM24-12-W-4
FM24-10-N-30-01
Flow monitors Series FM24; Viscosity compensated ...600mm²/s; Body Nickel plated brass; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication; Switch unit Wechsler; Connection 1"; Switching range 10...30L/min; Maximum pressure 250bar; U max. 250V; I max. 1,5A; Length 130mm
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1" 130 mm Change-over contact 250 V 1,5 A 250 bar 10...30 l/min FM24-10-N-30-01
FM24-34-W-60
Flow monitors Series FM24; Viscosity compensated ...600mm²/s; Body Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication; Switch unit Schließer; Connection 3/4"; Switching range 20...60L/min; Maximum pressure 300bar; U max. 250V; I max. 3A; Length 130mm
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
3/4" 130 mm NO contact 250 V 3 A 300 bar 20...60 l/min FM24-34-W-60
FM24-10-N-30-03
flow monitors series FM24; viscosity compensated ...600mm²/s; body nickel plated brass; for any mounting position; medium temperature max. 120°C; oil scale; application: monitoring of lubrication; switch unit: 2 change-over contact; connection G1"; switching range 10...30l/min; maximum pressure 250bar; U max. 250V; I max. 1,5A; length 130mm; 2. Contact opposite
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1" 130 mm Change-over contact 250 V 1,5 A 250 bar 10...30 l/min FM24-10-N-30-03
Flow monitors Series FM24

Flow monitors Series FM24

Viscosity compensated ...600mm²/s; Body Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication
Grundversion
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type Sequence
1" 130 mm NO contact 250 V 3 A 300 bar 15...45 l/min FM24-10-W-24-01 33060006
1" 130 mm NO contact 250 V 3 A 300 bar 15...45 l/min FM24-10-W-24-02 33060007
Flow monitors Series FM24

Flow monitors Series FM24

Viscosity compensated ...600mm²/s; Body Nickel plated brass; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication

Grundversion
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type Sequence
1" 130 mm Change-over contact 250 V 1,5 A 250 bar 15...45 l/min FM24-10-N-45-01 33060007
1" 130 mm Change-over contact 250 V 1,5 A 250 bar 30...110 l/min FM24-10-N-110-01 33060008
G 1" 130 mm NO contact 250 V 3 A 250 bar 2...8 l/min FM24-10-N-8 33060009
PT04-TCC112-001-420-01
pressure transmitter series PT04; body, wetted parts stainless steel AISI 316L; outlet signal 4...20 mA proportional to applied pressure; accuracy 0,5% of full pressure range; Tri-Clamp connection DN40; measuring range 0...1bar; electrical connection Round plug M12X1 (4-pin)
Pressure switch Series PS01

Pressure switch Series PS01

Change-over contact; Connection Brass; Setting scale; 250VAC/6A; 24VDC/2A; Protection class See Protection cap (Max. IP65)

Grundversion
Male thread Hysteresis range Overpressure protection Diaphragm Range of adjustment Type Sequence
G 1/4" 20 mbar 1 bar FKM 50...250 mbar PS01-14F-50/250-01 33070000
G 1/4" 5 mbar 0,5 bar NBR 50...250 mbar PS01-14E-10/50-01 33070001
PT04-12N-V1,5-420
Pressure transmitter Series PT04; Body, Wetted parts Stainless steel 1.4404; Outlet signal 4...20 mA Proportional to applied pressure; Accuracy 0,5% of full pressure range; Male thread G 1/4"; Measuring range -1...+1,5bar
Male thread Measuring range Type
G 1/4" -1...+1,5 bar PT04-12N-V1,5-420